SCBA Breathing Air Compressor Filling Station (EU Specification) – USAG Ansbach Fire Rescue
Department of Defense · Department of the Army · 0409 AQ HQ CONTRACT
Account requiredWhy it scored this way
Every reason behind the verdict rather than the headline one — which of your certifications match, how much runway is left, whether the work is your size, and what we would need to know to sharpen it.
Written against this notice and what you have told us about your company. Anything we do not know is marked [NEEDS INPUT] in the draft rather than guessed at — read it before you send it.
Start a free trial to draft these. Nothing is sent to an agency on your behalf, ever — you get a document to review, edit and submit yourself.
Compliance matrix
Every stated and implied requirement, its source section, whether it is mandatory, and where your response will address it.
Proposal outline
A submission skeleton where every required element is a heading with its source requirement quoted beneath it. You write the substance; nothing gets forgotten.
Questions to submit
Genuine ambiguities and requirements that disadvantage a smaller bidder, drafted as questions you can submit before the Q&A deadline.
Past performance write-ups
Which of your prior awards best match this requirement, and draft write-ups in the format the agency asked for.
Solicitation details
Solicitation number
PAN40926P0000028932
Notice type
Presolicitation
NAICS
333912
Product service code
4210
Set-aside
No Set aside used
Posted
2026-08-18
Response deadline
Sep 1, 2026, 1:00 PM UTC
Place of performance
KATTERBACH, DE-BY
Contracting contact
jean.c.silva2.mil@army.mil
Market intelligence
Account requiredWho wins this work, and what it pays
Comparable awards under NAICS 333912 at this agency — the incumbent, what they were paid, when their period of performance ends, and the real pricing distribution rather than the headline number. From public federal award records.
NOTICE: This pre?solicitation notice is issued for planning and informational purposes only and does not constitute a solicitation or commitment by the Government. All detailed specifications, instructions, and evaluation criteria will be provided in the forthcoming solicitation. DESCRIPTION: The 409th Contracting Support Brigade, Regional Contracting Office (RCO) Bavaria, intends to issue a Request for Quotation (RFQ) for the procurement, delivery, installation, and TÜV inspection/certification of one Self?Contained Breathing Apparatus (SCBA) Breathing Air Compressor Filling Station (EU Specification) for USAG Ansbach Fire Rescue. REQUIRED ITEM: SCBA Breathing Air Compressor Filling Station (EU Spec), including: • Breathing air compressor compliant with DIN EN 1012?1; breathing air quality per DIN EN 12021; 550 l/min delivery rate; 350 bar operating pressure; 4 compression stages; electric motor 15 kW / 50 Hz / 400 V; “Super Silent” enclosure. • Monitoring systems: capacitive filter moisture monitoring (normal/pre?warning/saturated), automatic shutdown/lockout on saturation, oil pressure monitoring, final?stage temperature monitoring, cycle counting, and software?based logbook. • 8?outlet “8S” filling configuration on front and rear panels; automatic condensate drain; external control panel with ON/OFF, emergency stop, and operating hours counter. • 6?way stainless steel wall?mounted filling console (1200 mm width) with 6 × 300 bar filling ports, throttles for CFRP cylinders, safety filling plugs, toggle valves with automatic venting, and 400 bar pressure gauge. • 2?port stainless steel filling bar (750 mm width), 2 × 200 bar filling connections, toggle?lever valves, swivel joints, 1?meter filling hoses with safety nipples, adjustable pressure reducer, TÜV?certified 225 bar safety valve, dual pressure gauges. • On?site TÜV acceptance, cybersecurity inspection, three pre?commissioning inspections of storage cylinders, and all associated travel/mileage. CRITICAL REQUIREMENT – COMPATIBILITY: All filling ports, fittings, hoses, safety filling plugs/nipples, and the compressor system must be 100% compatible and fully interoperable with the customer’s existing Draeger SCBA cylinders, including 300 bar CFRP cylinders, and the current breathing air infrastructure used by USAG Ansbach Fire Rescue. Non?compatible equipment will be determined technically unacceptable.
Contact
Point of contact
Jean Carlos Silva
Role
not stated on this notice — SAM publishes a role for only about 5% of them, so this may be a contract specialist rather than the contracting officer
Email
jean.c.silva2.mil@army.mil
Submit questions
Ambiguities and requirements worth clarifying, written as questions you can send before the deadline.
Opens in your own mail client, addressed and with a subject line — you write the message. GovSprint never sends anything on your behalf.
Emails open in your mail client and are sent from your address, so the reply comes back to you and the exchange stays yours. Confirm the correct channel and any question deadline on the notice before sending — many solicitations require questions in a specific way.