Department of Defense · Department of the Army · W7M6 USPFO ACTIVITY ILANG 182
Account requiredWhy it scored this way
Every reason behind the verdict rather than the headline one — which of your certifications match, how much runway is left, whether the work is your size, and what we would need to know to sharpen it.
Written against this notice and what you have told us about your company. Anything we do not know is marked [NEEDS INPUT] in the draft rather than guessed at — read it before you send it.
Start a free trial to draft these. Nothing is sent to an agency on your behalf, ever — you get a document to review, edit and submit yourself.
Compliance matrix
Every stated and implied requirement, its source section, whether it is mandatory, and where your response will address it.
Proposal outline
A submission skeleton where every required element is a heading with its source requirement quoted beneath it. You write the substance; nothing gets forgotten.
Questions to submit
Genuine ambiguities and requirements that disadvantage a smaller bidder, drafted as questions you can submit before the Q&A deadline.
Past performance write-ups
Which of your prior awards best match this requirement, and draft write-ups in the format the agency asked for.
Solicitation details
Solicitation number
W50S7T26QA010
Notice type
Combined Synopsis/Solicitation
NAICS
561210
Product service code
J012
Set-aside
No Set aside used
Posted
2026-08-12
Response deadline
Aug 31, 2026, 5:00 PM UTC
Place of performance
Peoria, IL
Contracting contact
emily.scully.1@us.af.mil
Market intelligence
Account requiredWho wins this work, and what it pays
Comparable awards under NAICS 561210 at this agency — the incumbent, what they were paid, when their period of performance ends, and the real pricing distribution rather than the headline number. From public federal award records.
(i) This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. All quotes provided shall be marked “Quote current until 30 September 2026.” This solicitation, W50S7T-26-Q-A010 is being issued as a Request for Quotation (RFQ). This solicitation is being posted as other than full and open, with a brand name requirement for Simplex (Johnson Controls) systems. The brand name justification will be posted with the solicitation. This acquisition is not set-aside for small business concerns. The solicitation incorporates provisions and clauses by reference and may be accessed electronically at www.acquisition.gov . All clauses and provisions please see attached solicitation. The Government intends to award one (1) award to one (1) contractor. The awarded Purchase Order (PO) shall be awarded with a one (1) year period of performance from 30 September 2026 to 29 September 2027. There will be an optional site visit 18 August 2026 at 1:00PM Central Daylight Time at the Peoria Air National Guard Base, Peoria Illinois. (ii) Requirement Line Items: Line Item 0001 -Node 1- B536 CERFP Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. Line Item 0002 - Node 3 - B636 Security Forces Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. Line Item 0003 - Node 4 - B730 Engine Shop Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. Line Item 0004- Node 5 - B830 Avionics Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system. Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. Line Item 0005- Node 6 - B834 AGE- Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0006 Node 7 - B530 POL Complex- Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0007 Node 8 - B728 Base Supply- Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system. Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0008 Node 9 - B280 Munitions- Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0009 Node 10 - B836 Aerial Port- Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0010 Node 11 - B528 Civil Engineer- Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0011 Node 12 - B628 Headquarters- Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). Tie in existing Very Early Warning Smoke Detection system (VESDA) Tie in existing communications vault suppression / detection system. Tie in existing kitchen detection and suppression notification systems. All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636 CLIN 0012 Node 13 - B620 Recruiting- Install ethernet compatible communications package to recently installed FACP that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Upgrade existing addressable devices compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0013 Node 14 - B820 Vehicle Maintenance- Remove and replace existing fire alarm control panel (FACP).Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0014 Node 15 - B541 Fire Department - Install ethernet compatible communications package to recently installed FACP that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Upgrade existing addressable devices compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0015 Node 16 - B615 Lift Station - Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system. All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0016 Node 17 - B831 Pump House - Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system. All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0017 Node 20 - B835 Combat Comm Cold Storage- Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0018 Node 21 - B630 Combat Comm / Army Band - Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636 CLIN 0019 B636 Node 22 Install TSW - Remove existing TSW from site Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Install new TSW with Windows11 platform or similar that is compatible with COINv3 standards. Install new graphics and user interface that have been approved by the COR or designated representative, that at a minimum includes a base map, building numbers and approved notifications. Install minimum 30 minute battery backup power supply for TSW to sustain device in the event of power service interruption. CLIN 0020 B541 Node 23 Install TSW - Remove existing TSW from site Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Install new TSW with Windows11 platform or similar that is compatible with COINv3 standards. Install new graphics and user interface that have been approved by the COR or designated representative, that at a minimum includes a base map, building numbers and approved notifications. Install minimum 30 minute battery backup power supply for TSW to sustain device in the event of power service interruption. CLIN 0021 Node 24 B320 - Comm/CRG - Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0022 Node 25 - B634 Flight Operations - Install ethernet compatible communications package to recently installed FACP that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Upgrade existing addressable devices compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0023 Node 26 - B837 Emergency Management - Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system. Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. CLIN 0024 Node 27 – Hazmart - Remove and replace existing fire alarm control panel (FACP). Install ethernet compatible communications package that will be compatible with COINv3 standards to develop an infrastructure that meets current reporting requirements. Replace existing initiating devices with addressable devices, compatible with the new system Tie in existing Mass Notification Warning System (MNWS). All units will be installed, programmed and tested to ensure functionality and reporting back to the central stations located in B541 and B636. (iii) Description of Requirement: This is request for proposal for a construction to provide The Repair for Base Fire Alarm System for the Illinois Air National Guard (ILANG). The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and non-personal services necessary to remove and replace existing fire alarm panels in various buildings throughout the base in accordance with UFC 3-600-01 and ANG ETL 15-01-03 standards. Remove and replace existing initiating devices with addressable units. Upgrade all communication devices from existing fiber between buildings to COINv3 ethernet compatible units. Replace existing TrueSite Workstations (TSW) with new, COINv3 compatible units. Replace existing TrueSite Workstations (TSW) with new COINv3 compatible TSWs with upgraded graphics and nomenclature. All units will be installed, programmed and tested throughout each facility and at each TSW. Fire alarm panels and workstations shall be manufactured by Simplex to ensure compatibility and interoperability with recently installed systems throughout the base. (iv) Dates and Location: The period of performance will be 30 September 2026 through 29 September 2027. The location will be Peoria Air National Guard Base, Peoria Illinois. (v) Solicitation provisions and clauses shall be found on the attached Solicitation # W50S7T26A010. Quotations shall be submitted prior to the closing date and time listed below. All quotations shall be emailed to 1st Lt Nicholas Marzinzik at nicholas.marzinzik@us.af.mil and SSgt Emily Scully at emily.scully.1@us.af.mil. Quotations are due 31 August 2026 @ 12:00 PM CDT. *Acceptance via email* All questions shall be submitted by 21 August 2026 at 1200 CDT. The government is not obligated to answer questions. The submission of the documentation specified below will constitute the quoter’s acceptance of the terms and conditions of the description of requirement in the RFP. Questions should be posted by the due date listed above. It is the Government’s intention to award without discussion. Vendors are encouraged to present their best Proposal and prices in their initial submission. The Government reserves the right to hold discussions. (vii) NG Agency Protest Program is intended to encourage interested parties to seek resolution of their concerns with the National Guard (NG) as an Alternative Dispute Resolution forum, rather than filing a protest with the Government Accountability Office (GAO) or other external forum. Contract award or performance is suspended during the protest to the same extent, and within the same time periods as if filed at the GAO. The NG protest decision goal is to resolve protests within 35 calendar days from filing. An agency protest may be filed with either the Contracting Officer or the NG Agency’s Protest Decision Authority, but not both, in accordance with NG protest procedures. To be timely, the protests must be filed with the periods specified in FAR 33.103. To file a protest under the NG Agency Protest Program, the protest must request resolution under that program and be sent to the address below: National Guard Bureau Office of the Director of Acquisitions/ Head of Contracting Activity ATTN: NGB-AQ-O 111 S. George Mason Dr. Arlington, VA 22204 Email: ng.ncr.ngb-arng.mbx.ngb-task-order-ombudsman@mail.mil All other agency-level protests should be sent to the Contracting Officer for resolution at the address in the solicitation. See FAR clause 52.233-2. NG Public-facing, general Protest information is found at: https://www.nationalguard.mil/Leadership/Joint-Staff/Special-Staff/Director-of-Acquisitions/ Directorate of Acquisitions information for the contracting enterprise is found at: https://gko.portal.ng.mil/ngb/STAFF/D01/D01/OI/Protests%20and%20Complaints/Forms/AllItems.aspx
Contact
Point of contact
Emily Scully
Role
not stated on this notice — SAM publishes a role for only about 5% of them, so this may be a contract specialist rather than the contracting officer
Email
emily.scully.1@us.af.mil
Secondary
nicholas.marzinzik@us.af.mil
Submit questions
Ambiguities and requirements worth clarifying, written as questions you can send before the deadline.
Opens in your own mail client, addressed and with a subject line — you write the message. GovSprint never sends anything on your behalf.
Emails open in your mail client and are sent from your address, so the reply comes back to you and the exchange stays yours. Confirm the correct channel and any question deadline on the notice before sending — many solicitations require questions in a specific way.