GovSprint
← Back to today

NEXODOSE DOSE MONITOR

Department of Veterans Affairs · 255-NETWORK CONTRACT OFFICE 15 (36C255)
Account requiredWhy it scored this way

Every reason behind the verdict rather than the headline one — which of your certifications match, how much runway is left, whether the work is your size, and what we would need to know to sharpen it.

Solicitation documents

The requirements that decide a bid — bonding, clearances, experience minimums, page limits — live in the attachments, not in the notice above. Start a free trial to upload them and have them read.

Draft the paperwork

Written against this notice and what you have told us about your company. Anything we do not know is marked [NEEDS INPUT] in the draft rather than guessed at — read it before you send it. Federal notices routinely put the real requirement in an attachment; adding the documents above makes every one of these materially better.

Start a free trial to draft these. Nothing is sent to an agency on your behalf, ever — you get a document to review, edit and submit yourself.

What would disqualify you

Read straight from the solicitation documents: the bonding, clearances, insurance minimums, experience thresholds and deadlines that decide whether you can bid at all — before you write a word.

Sources Sought response

A complete draft response — capability statement, relevant past performance, business size and socioeconomic status, and answers to the agency's specific questions.

Questions to submit

Genuine ambiguities and requirements that disadvantage a smaller bidder, drafted as questions you can submit before the Q&A deadline.

Past performance write-ups

Which of your prior awards best match this requirement, and draft write-ups in the format the agency asked for.

Solicitation details

Solicitation number
36C25527Q0017
Notice type
Sources Sought
NAICS
541519
Set-aside
Unrestricted
Posted
2026-10-19
Response deadline
Oct 29, 2026, 4:00 PM UTC
Place of performance
Kansas City, MO
Contracting contact
veronica.flores@va.gov

Market intelligence

Account requiredWho wins this work, and what it pays

Comparable awards under NAICS 541519 at this agency — the incumbent, what they were paid, when their period of performance ends, and the real pricing distribution rather than the headline number. From public federal award records.

Statement of work, as posted

This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does not obligate the Government to award a contract. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research, to make appropriate acquisition decisions, and to gain knowledge of potential qualified businesses capable of providing the following: DoseMonitor/Nexodose Management for Kansas and Missouri VA Medical Facilities *** See Statement of Work below for details *** If this is within your capability, please respond with the information below: Company Name Address Point of Contact Phone, Fax, and Email UEI number GSA Contract (as applicable) Capability Statement that clearly and convincingly identifies your ability to fulfill this requirement. Brochures of product being offered to include specifications. Authorized service provider letter from OEM Interested firms are reminded that in accordance with FAR 4.203, prospective contractors shall complete electronic annual representations and certifications to be considered for award. In addition, FAR 4.203 states that prospective contractors shall be registered in the System for Award Management (www.SAM.gov) database. All Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Businesses (VOSB) shall be verified in SBA at Small Business Search . Point of Contact for this Sources Sought is: veronica.flores@va.gov Department of Veterans Affairs Network Contracting Office -15 3450 S. 4th Street Trafficway Leavenworth, KS. 66048 STATEMENT OF WORK (SOW) Radiation Dose Tracking Software Maintenance, Support, and Bi-Directional HL7 Interface Services (DoseMonitor/Nexodose) Department of Veterans Affairs Veterans Integrated Service Network (Legacy VISN) Kansas and Missouri VA Medical Facilities: Period of Performance (Base Year): 02/01/2027 – 01/31/2028 Period of Performance (Option Year 1): 02/01/2028 – 01/31/2029 1. BACKGROUND Kansas and Missouri VA Medical Facilities currently utilizes the DoseMonitor (Nexodose) radiation dose tracking and monitoring software platform to capture, track, and report patient radiation exposure associated with diagnostic and interventional imaging procedures. This system supports clinical safety, regulatory compliance (e.g., accreditation and federal radiation safety reporting), and quality assurance functions for Radiology and related imaging services at the facility identified above. The facility's DoseMonitor/Nexodose environment will require that it interfaces upon conversion, bidirectionally with the site's electronic health record (Oracle Health/Cerner) via HL7 messaging to support orders and results exchange, and includes an outbound API/HL7 feed for downstream data consumption. Continued annual maintenance and support (M&S) is required to sustain system availability, vendor-supplied upgrades/updates, and interface reliability across the Production and Test environments. 2. PURPOSE / SCOPE The Contractor shall provide annual software maintenance and support for the DoseMonitor/Nexodose platform, the outbound API/HL7 interface, and the bi-directional HL7 interfaces between DoseMonitor/Nexodose and the site's Cerner environment (both Production and Test instances), and shall perform one-time installation/configuration of the bi-directional Cerner HL7 interfaces in both the Production and Test environments, in accordance with the Contract Line Item Numbers (CLINs) identified in Section 4 below. This SOW covers a base period of performance and one (1) option period, as detailed in Section 5. 3. APPLICABLE DOCUMENTS The Contractor shall perform all work in accordance with: VA Handbook 6500 and applicable VA Information Security requirements HIPAA Privacy and Security Rules (45 CFR Parts 160, 164) Health Level Seven (HL7) v2.x messaging standards, as applicable to the interfaces described herein Section 508 of the Rehabilitation Act (accessibility standards), where applicable to any software deliverables VA Directive 6102, VA Enterprise Architecture, and applicable VISN / facility local IT and Biomedical Engineering policies Manufacturer/vendor technical specifications for DoseMonitor/Nexodose 4. CONTRACT LINE ITEMS (CLINs) AND TASK REQUIREMENTS CLIN Description Qty/UOM DM-10-KAN-BY-AM&S — DoseMonitor/Nexodose Annual Maintenance & Support 1 EA DM-10-KAN-BY-OB — Outbound API/HL7 Annual Maintenance & Support 2 EA DM-10-KAN-BY-CERNER PRO — Bi-Directional (Orders/Results) HL7 Interface to Cerner, PRODUCTION 1 EA DM-10-KAN-BY-CERN-HL7-P — Bi-Directional Interface, Cerner PRODUCTION, Annual M&S (includes all upgrades/updates) 1 EA DM-10-KAN-BY-CERNER TEST — Bi-Directional (Orders/Results) HL7 Interface to Cerner, TEST 1 EA DM-10-KAN-BY-CERN-HL7-T — Bi-Directional Interface, Cerner TEST, Annual M&S (includes all upgrades/updates) 1 EA Base Period Total: 4.1 CLIN 0001 — DoseMonitor/Nexodose Annual Maintenance & Support The Contractor shall provide annual software maintenance and technical support for the DoseMonitor/Nexodose application, to include: Access to a technical support/help desk during standard business hours (minimum 8:00 AM – 5:00 PM local facility time, Monday–Friday, excluding federal holidays), with a defined escalation path for critical (system-down) issues. All vendor-issued software updates, patches, and version upgrades released during the period of performance, at no additional cost. Remote diagnostic and troubleshooting support for software defects, performance issues, and configuration errors. Proactive notification of known issues, security patches, and end-of-life/end-of-support milestones affecting the software. Software license renewal/maintenance to ensure continued authorized use of the application for the period of performance. 4.2 CLIN 0002 — Outbound API/HL7 Annual Maintenance & Support The Contractor shall provide annual maintenance and support for the outbound API/HL7 interface(s) used to export dose-tracking data from DoseMonitor/Nexodose to downstream consuming systems, to include: Monitoring and support of outbound message transmission to ensure data integrity and timely delivery. Troubleshooting and remediation of interface errors, message failures, or mapping issues. Support for any vendor-side configuration changes required due to upgrades to the DoseMonitor/Nexodose platform. Documentation of the outbound interface specification, updated as changes occur. 4.3 CLIN 0003 — Bi-Directional HL7 Interface to Cerner, PRODUCTION (One-Time Installation) The Contractor shall design, configure, install, and validate a bi-directional HL7 interface between DoseMonitor/Nexodose and the facility's Cerner Production environment to support orders and results exchange, to include: Interface build and configuration in coordination with facility Biomedical Engineering, Radiology, and Health Informatics/IT staff. HL7 message mapping (e.g., ORM/ORU or applicable message types) between DoseMonitor/Nexodose and Cerner. End-to-end interface testing and validation in the Production environment prior to go-live, including a documented test plan and results. Coordination of a go-live/cutover date with facility stakeholders and the VA Interface Team. Delivery of as-built interface documentation, including message specifications and data mapping. 4.4 CLIN 0004 — Bi-Directional Interface, Cerner PRODUCTION, Annual Maintenance & Support Following successful installation under CLIN 0003, the Contractor shall provide annual maintenance and support for the Production bi-directional HL7 interface, to include: All upgrades and updates to the interface engine/configuration required to maintain compatibility with DoseMonitor/Nexodose and Cerner throughout the period of performance. Ongoing interface monitoring support and troubleshooting of message failures or data discrepancies. Support for interface re-validation following any Cerner or DoseMonitor/Nexodose upgrade that affects message exchange. 4.5 CLIN 0005 — Bi-Directional HL7 Interface to Cerner, TEST (One-Time Installation) The Contractor shall design, configure, install, and validate a bi-directional HL7 interface between DoseMonitor/Nexodose and the facility's Cerner Test/non-production environment, mirroring the scope described in Section 4.3, to support pre-production testing, patch validation, and upgrade regression testing without impact to the Production environment. 4.6 CLIN 0006 — Bi-Directional Interface, Cerner TEST, Annual Maintenance & Support Following successful installation under CLIN 0005, the Contractor shall provide annual maintenance and support for the Test bi-directional HL7 interface, mirroring the scope described in Section 4.4, to ensure the Test environment remains a reliable, up-to-date proving ground for changes prior to Production deployment. 5. PERIOD OF PERFORMANCE Period Dates Base Period 02/01/2027 – 01/31/2028 Option Period 1 02/01/2028 – 01/31/2029 6. PLACE OF PERFORMANCE Work under this SOW shall be performed primarily remotely from the Contractor's facility. On-site support at Legacy VISN sites include: Eastern Kansas: Topeka, KS, Eastern Kansas: Leavenworth, KS, Wichita, KS, Kansas City, MO, St. Louis, MO, Columbia, MO, Poplar Bluff, MO, Marion, IL may be required for initial interface installation, go-live support, or troubleshooting that cannot be resolved remotely, at no additional cost to the Government unless otherwise negotiated and documented in the contract. 7. GOVERNMENT FURNISHED INFORMATION / EQUIPMENT The Government will provide: Remote access credentials/VPN access as required for Contractor support staff, subject to VA background investigation and PIV/security requirements (see Section 9). Access to relevant technical points of contact within facility Biomedical Engineering, Health Informatics, and IT/OI&T staff. Existing system documentation, network diagrams, and interface specifications as available. 8. DELIVERABLES Deliverable Due Date Interface Test Plan (Production & Test) Prior to installation/go-live Interface Validation/Test Results Report Upon completion of interface testing, prior to go-live As-Built Interface Documentation Within 10 business days of go-live Monthly/Quarterly Maintenance Status Report (if required by COR) Per COR-specified cadence Annual Software License/Maintenance Renewal Confirmation Prior to expiration of current M&S term 9. SECURITY AND PRIVACY REQUIREMENTS The Contractor shall comply with all applicable VA information security and privacy requirements, including but not limited to: Execution of a Business Associate Agreement (BAA) if the Contractor will have access to Protected Health Information (PHI). Compliance with VA Handbook 6500 for information security. Completion of VA Privacy and Information Security Awareness training and signed Rules of Behavior by all Contractor personnel prior to system access. Any remote access to VA systems shall be through VA-approved, encrypted connections only. No PHI or PII shall be removed from VA systems or transmitted outside of VA-approved channels. Contractor personnel requiring recurring access to VA networks/systems shall undergo background investigation (e.g., NACI or higher, as determined by the VA Personnel Security office) commensurate with position sensitivity. 10. QUALITY ASSURANCE / ACCEPTANCE CRITERIA All one-time interface installations (CLINs 0003 and 0005) shall be deemed complete upon successful bi-directional message exchange testing, validated jointly by the Contractor and designated facility/VISN 15 technical staff, and formal written acceptance by the Contracting Officer's Representative (COR). Annual maintenance and support services (CLINs 0001, 0002, 0004, 0006) shall be monitored via a Quality Assurance Surveillance Plan (QASP), to be maintained by the COR, measuring support responsiveness, resolution timeliness, and system uptime/availability.

Contact

Point of contact
Betty Flores
Role
not stated on this notice — SAM publishes a role for only about 5% of them, so this may be a contract specialist rather than the contracting officer
Email
veronica.flores@va.gov
Submit questions

Ambiguities and requirements worth clarifying, written as questions you can send before the deadline.

Open email
Capability response

Introduce your firm against this requirement for a Sources Sought or market research notice.

Open email
Request documents

Ask for attachments, drawings or specifications referenced in the notice but not posted.

Open email
Add me to interested vendors

Ask to be listed as an interested vendor so other bidders can find you for teaming.

Open email

Opens in your own mail client, addressed and with a subject line — you write the message. GovSprint never sends anything on your behalf.

Emails open in your mail client and are sent from your address, so the reply comes back to you and the exchange stays yours. Confirm the correct channel and any question deadline on the notice before sending — many solicitations require questions in a specific way.