GovSprint
← Back to today

TECHNOLOGY LICENSING OPPORTUNITY: Multi-Channel Atomic Magnetometer (MCAM)

Department of Energy · TRIAD - DOE CONTRACTOR
Account requiredWhy it scored this way

Every reason behind the verdict rather than the headline one — which of your certifications match, how much runway is left, whether the work is your size, and what we would need to know to sharpen it.

Draft the paperwork

Written against this notice and what you have told us about your company. Anything we do not know is marked [NEEDS INPUT] in the draft rather than guessed at — read it before you send it.

Start a free trial to draft these. Nothing is sent to an agency on your behalf, ever — you get a document to review, edit and submit yourself.

Sources Sought response

A complete draft response — capability statement, relevant past performance, business size and socioeconomic status, and answers to the agency's specific questions.

Questions to submit

Genuine ambiguities and requirements that disadvantage a smaller bidder, drafted as questions you can submit before the Q&A deadline.

Past performance write-ups

Which of your prior awards best match this requirement, and draft write-ups in the format the agency asked for.

Solicitation details

Solicitation number
S-133667
Notice type
Special Notice
NAICS
334516
Product service code
6635
Set-aside
No Set aside used
Posted
2026-07-17
Response deadline
Dec 13, 2026, 12:00 AM UTC
Place of performance
Los Alamos, NM
Contracting contact
licensing@lanl.gov

Market intelligence

Account requiredWho wins this work, and what it pays

Comparable awards under NAICS 334516 at this agency — the incumbent, what they were paid, when their period of performance ends, and the real pricing distribution rather than the headline number. From public federal award records.

Statement of work, as posted

Unlike conventional multichannel atomic magnetometers that require one vapor cell and one optical system for each sensing channel, the patented Multi-Channel Atomic Magnetometer (MCAM) architecture from Los Alamos National Laboratory replaces many independent atomic magnetometers with a single shared vapor cell and optical system that simultaneously generates multiple independent sensing channels. MCAM is a non-cryogenic multi-channel optical quantum sensor in a single module that captures ultra-faint biomagnetic signals from the brain, heart and other sources with sensitivity approaching that of the cryogenic SQUID-based systems that have defined the field for decades. MCAM delivers that performance at roughly one-tenth the per-channel cost without a drop of liquid helium. The module pairs one large alkali-metal vapor cell with broad pump and probe laser beams read out by a photodiode array, providing 16 independent sensing channels in a single housing, scaling into helmet-style arrays of hundreds of channels, and flexing around the patient rather than forcing the patient into a fixed cryogenic dewar. Together, these attributes more easily allow for magnetoencephalography, magnetocardiography and magnetic-particle imaging while accelerating overall magnetic imaging workflows. Ongoing development is aimed at extending the sensing architecture from the centimeter scale characterized in the current prototype toward micrometer-scale spatial resolution, opening a path into cellular-scale magnetic imaging that current cryogenic and room-temperature arrays cannot address. How it Works The MCAM module operates on the spin-exchange relaxation-free (SERF) regime, in which atomic spins of alkali-metal atoms inside a large, sealed vapor cell are aligned by a circularly polarized broad pump laser beam through optical pumping and then interrogated by a linearly polarized broad probe beam propagating along a nearly parallel path. An external magnetic field of interest tilts the aligned atomic spins by an angle proportional to the field strength, and that tilt rotates the polarization plane of the probe beam through the Faraday effect; a photodiode array reads the optical rotation simultaneously at multiple points across the cell, with each photodiode pixel reporting on its own localized sensing volume. A buffer gas inside the cell restricts atomic motion so that the small cell volumes behind each pixel behave as independent sensing channels, a rear mirror folds the beams back through the cell to shorten the stand-off distance to the magnetic source, and transparent Pyrex wire heaters hold the cell at the operating temperature needed for SERF operation. Technology Description The patented shared-cell architecture generates multiple independent sensing channels from a single vapor cell, a single pump beam, a single probe beam, and a single detector array. A pair of broad, co-propagating laser beams, one for optical pumping and the other for probing, traverses the shared vapor cell to manipulate the internal atomic spins, converting the local magnetic field distribution into a spatially resolved optical signal that is read out by a multi-pixel photodetector. Because the buffer gas inside the cell restricts atomic diffusion, each pixel of the detector reports on its own small, spatially distinct region of the cell; therefore, the single module yields a two-dimensional map of the local magnetic field rather than a single-point measurement. Operation in the SERF regime, together with an integrated heating and shielding arrangement and a fold-back optical geometry that shortens the distance from the sensing volume to the magnetic source, sets the sensitivity floor in the low tens of femtotesla per root hertz at low frequency. A development path has been identified to reduce the effective sensing-volume scale from the roughly 1 cm per-channel footprint of the current prototype toward the 1 ?m range, which would extend the platform from whole-organ mapping into micro-scale magnetic imaging regimes. Architecturally, the MCAM module is engineered for arrays. Because all channels within a single module share one vapor cell, one laser pair, and one optics assembly, the per-channel parts count and tuning effort drop sharply versus designs that stack many single-channel sensors. Fiber-optic coupling between the laser sources and each sensor head lets modules be repositioned independently, so many modules can be tiled into a conformal helmet or surface array that adapts to head or torso shape and supports configurations that rigid large-cell predecessors cannot accommodate. The design is compatible with several alkali-metal and buffer-gas options and with per-module bias coils that allow each module to be tuned individually inside a larger array. Advantages Development path toward micrometer-scale spatial resolution, a roughly four-order-of-magnitude improvement over the current centimeter-scale prototype and an enabler of cellular-scale magnetic imaging Sensitivity at the low tens of femtotesla per root hertz, comparable to cryogenic SQUID arrays, while using a warm vapor, non-cryogenic architecture Roughly tenfold per-channel cost reduction by sharing one vapor cell, one laser pair and one optics set across 16 channels No liquid cryogens, eliminating recurring cryogen costs and simplifying siting, maintenance and shielding Fiber-coupled, repositionable sensor heads that conform to the patient rather than forcing the patient into a fixed dewar Scalable into helmet-style arrays of hundreds of channels, including a size-adjustable pediatric configuration Shorter sensor-to-source stand-off via rear-mirror beam folding, sharpening spatial resolution of biomagnetic sources Market Applications Medical Diagnostic Imaging (magnetoencephalography systems for epilepsy, stroke and neurodegenerative workups; magnetocardiography for arrhythmia and ischemia screening) Pediatric and Adaptive Neuroimaging (size-adjustable MEG helmets, point-of-care brain monitoring) Micro-scale Biomagnetic Imaging (single-neuron and small-circuit brain activity mapping, high-resolution cardiac tissue mapping) Cancer Diagnostics (magnetic nanoparticle imaging for tumor localization and targeted-therapy tracking) Magnetic Resonance Imaging (low-field/ultra-low field, portable MRI, functional brain imaging) Sensing (low-frequency antennas for underground or undersea links, geomagnetic surveying) Instrumentation (fundamental physics, biomagnetism laboratories, multichannel sensor R&D) Development Status: TRL 4 U.S. Patent No. 11,105,865 LA-UR-26-25904 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology m.lanl.gov/tech-search

Contact

Point of contact
Kathleen McDonald
Role
not stated on this notice — SAM publishes a role for only about 5% of them, so this may be a contract specialist rather than the contracting officer
Email
licensing@lanl.gov
Secondary
licensing@lanl.gov
Submit questions

Ambiguities and requirements worth clarifying, written as questions you can send before the deadline.

Open email
Capability response

Introduce your firm against this requirement for a Sources Sought or market research notice.

Open email
Request documents

Ask for attachments, drawings or specifications referenced in the notice but not posted.

Open email
Add me to interested vendors

Ask to be listed as an interested vendor so other bidders can find you for teaming.

Open email

Opens in your own mail client, addressed and with a subject line — you write the message. GovSprint never sends anything on your behalf.

Emails open in your mail client and are sent from your address, so the reply comes back to you and the exchange stays yours. Confirm the correct channel and any question deadline on the notice before sending — many solicitations require questions in a specific way.