WWYK220006 - RENOVATE CHILLED WATER CIRCUIT 3, B3001
Department of Defense · Department of the Air Force · FA8137 AFSC PZIOC
Account requiredWhy it scored this way
Every reason behind the verdict rather than the headline one — which of your certifications match, how much runway is left, whether the work is your size, and what we would need to know to sharpen it.
Written against this notice and what you have told us about your company. Anything we do not know is marked [NEEDS INPUT] in the draft rather than guessed at — read it before you send it.
Start a free trial to draft these. Nothing is sent to an agency on your behalf, ever — you get a document to review, edit and submit yourself.
Sources Sought response
A complete draft response — capability statement, relevant past performance, business size and socioeconomic status, and answers to the agency's specific questions.
Questions to submit
Genuine ambiguities and requirements that disadvantage a smaller bidder, drafted as questions you can submit before the Q&A deadline.
Past performance write-ups
Which of your prior awards best match this requirement, and draft write-ups in the format the agency asked for.
Solicitation details
Solicitation number
WWYK22006
Notice type
Sources Sought
NAICS
236220
Set-aside
Small Business Set Aside - Total
Posted
2026-08-05
Response deadline
Aug 20, 2026, 7:00 PM UTC
Place of performance
Tinker AFB, OK
Contracting contact
isaac.demmers@us.af.mil
Market intelligence
Account requiredWho wins this work, and what it pays
Comparable awards under NAICS 236220 at this agency — the incumbent, what they were paid, when their period of performance ends, and the real pricing distribution rather than the headline number. From public federal award records.
THIS POSTING IS FOR TINKER AFB - MAC BOA HOLDER ONLY Tinker AFB (TAFB) Oklahoma is soliciting a source’s sought to see if there are any contractors capable of completing the requirements found in the attached project Statement of Work (SOW) and drawings. If respondent is only capable of being a General Contractor, please provide your average percentage for Design, G&A, Overhead, Profit and Bonds. WWYK220006 - Renovate Chilled Water Circuit 3, B3001. This is a Concept Design. Recommendations #13 para 5a on pgs 11-12 and #14 para 5.b on pg 12 of the Chilled Water Distribution Study by ZRHD on 5 Oct 2020. Circuit #3: remove old Circuit #3 piping to multiple fan decks and re-feed from new Circuit #3. Remove reverse return piping and connect to the new Circuit #3. Replace 2" supply and return to AHU's PR65 and PR66 with 4" supply and return piping. Eliminate tertiary pupmps CHWP-PR65 and CHWP-PR66. Relocate from over workspaces and mezzanines to the best located aisle for ease of access and maintenance. The work to be performed under the terms of this Order consists of furnishing all design/engineering services, materials, labor, plant, tools, transportation, equipment, testing services, quality control and incidentals required to accomplish the removal of the existing Chilled Water Circuit #3 piping that extends to multiple fan decks. The work will also consist of installing a new Circuit #3, relocating the piping away from workspaces and mezzanines to the east aisle way when possible, for ease of access and maintenance and demolition of old steam lines at Tinker Air Force Base (AFB), Oklahoma (reference the project drawings for additional location information). The Contractor’s work elements must fully comply with the Government’s issued contract documents, as well as all governing codes, Tinker AFB Specifications, and Technical Specifications. The services to be performed under this contract are non-military unique and are commonly available in the local market area and have routinely been performed by companies within the small business set-aside, two step sealed bid program. Project specific documents are attached to this posting. If you are a prime contractor experiencing any difficulty at receiving or accessing the project specific documents, send an email request to Contracting Points of Contact listed. If you would like to express your interest in this project please Email SSgt Isaac Demmers at isaac.demmers@us.af.mil by 20 August 2026 @ 1400 (2:00 PM) CST, stating so. THIS POSTING IS FOR TINKER AFB - MAC BOA HOLDER ONLY
Contact
Point of contact
Isaac Demmers
Role
not stated on this notice — SAM publishes a role for only about 5% of them, so this may be a contract specialist rather than the contracting officer
Email
isaac.demmers@us.af.mil
Secondary
darian.permetter@us.af.mil
Submit questions
Ambiguities and requirements worth clarifying, written as questions you can send before the deadline.
Opens in your own mail client, addressed and with a subject line — you write the message. GovSprint never sends anything on your behalf.
Emails open in your mail client and are sent from your address, so the reply comes back to you and the exchange stays yours. Confirm the correct channel and any question deadline on the notice before sending — many solicitations require questions in a specific way.