GovSprint
← Back to today

TECHNOLOGY LICENSING OPPORTUNITY: UltraGraph Membrane Extraction System

Department of Energy · TRIAD - DOE CONTRACTOR
Account requiredWhy it scored this way

Every reason behind the verdict rather than the headline one — which of your certifications match, how much runway is left, whether the work is your size, and what we would need to know to sharpen it.

Draft the paperwork

Written against this notice and what you have told us about your company. Anything we do not know is marked [NEEDS INPUT] in the draft rather than guessed at — read it before you send it.

Start a free trial to draft these. Nothing is sent to an agency on your behalf, ever — you get a document to review, edit and submit yourself.

Sources Sought response

A complete draft response — capability statement, relevant past performance, business size and socioeconomic status, and answers to the agency's specific questions.

Questions to submit

Genuine ambiguities and requirements that disadvantage a smaller bidder, drafted as questions you can submit before the Q&A deadline.

Past performance write-ups

Which of your prior awards best match this requirement, and draft write-ups in the format the agency asked for.

Solicitation details

Solicitation number
S-133595
Notice type
Special Notice
NAICS
334516
Product service code
6640
Set-aside
No Set aside used
Posted
2026-06-05
Response deadline
Sep 30, 2026, 11:00 PM UTC
Place of performance
Los Alamos, NM
Contracting contact
licensing@lanl.gov

Market intelligence

Account requiredWho wins this work, and what it pays

Comparable awards under NAICS 334516 at this agency — the incumbent, what they were paid, when their period of performance ends, and the real pricing distribution rather than the headline number. From public federal award records.

Statement of work, as posted

The UltraGraph Membrane Extraction System from Los Alamos National Laboratory is a compact, modular device that separates and recovers targeted materials from liquid mixtures using an ultra-thin graphene membrane. The system achieves mass transfer performance comparable to conventional separation equipment with active areas 250 times larger. Its building-block design, chemically stable materials and compatibility with standard laboratory fittings allow it to serve a wide range of applications in chemical separations, recovery purifications and biological sample preparation. Organizations can integrate the UltraGraph system into existing laboratory infrastructure with minimal modification, reducing the cost and complexity of adoption. How it Works The UltraGraph system flows two different liquids through separate microchannels etched into quartz substrates, with a three-layer membrane positioned between them. The membrane consists of a monolayer sheet of graphene held between two porous formvar polymer films, each approximately 125 nanometers thick. The formvar layers are permeable, allowing liquid to reach the graphene surface, while the graphene itself blocks the bulk fluids but permits selected ions or particles to transfer across. Liquids can run co-currently or counter-currently depending on the separation task, enabling controlled mass transfer, ion exchange or heat exchange without the two fluids ever mixing. The assembly is secured between steel plates that compress the quartz chips and ETFE gaskets together, forming a leak-resistant seal that connects to standard screw-port fittings. Technical Description The graphene at the center of the membrane is grown via chemical vapor deposition on copper foil and transferred onto formvar support films using a proprietary process that is one to two orders of magnitude faster than conventional PMMA-based transfer methods. The formvar films have tunable porosity ranging from 20% to 60%. At approximately 125 nanometers thick with an elastic modulus of 7.8 GPa, the formvar provides sufficient mechanical support for atomically thin graphene across 100-micrometer-wide channels at flow rates up to 25 microliters per minute. The graphene layer can be functionalized with oxide groups, nanoparticles or engineered pores to adjust selectivity for specific ions or molecules. The total membrane thickness is approximately 250 nanometers, which is orders of magnitude thinner than membranes used in conventional microfluidic separation devices. The quartz microchannel substrates can be configured in patterns ranging from single channels to branching multi-channel networks and radially extending circular designs. In laboratory testing, the system achieved a pH change of approximately 4 in deionized water contacted with an organic triethylamine solution across the graphene membrane, matching the output of a commercial system whose mass transfer area was 250 times larger. The four-channel counter-current configuration demonstrated 17.4% triethylamine transfer at 15 microliters per minute, on par with that commercial benchmark. The modular stacking design allows additional substrate-membrane pairs to be layered to increase throughput without redesigning the housing, and scaling estimates project that a cylindrical multi-layer assembly could process 26 milliliters per minute across more than 1,000 channels. Because the quartz chips are reusable and the membrane materials are inexpensive to produce, the system lowers the economic discard limit for recoverable materials that might otherwise be classified as waste. Advantages High efficiency in a compact form factor — performs comparably to systems with separation areas 250 times larger Tunable selectivity — the graphene membrane can be chemically modified to target specific ions, molecules or particles Modular and scalable — additional chip-and-membrane layers can be stacked to increase capacity without a full redesign Chemically stable and radiation resistant — formvar support layers are inert to most chemicals and tolerate radiation exposure, suiting the system to demanding operating environments Low-cost and reusable components — quartz chips can be reused, membranes are inexpensive to manufacture and standard connectors simplify integration Leak-resistant design — ETFE gaskets and a compression housing address the leakage issues common in prior microfluidic membrane systems Market Applications Water Treatment and Desalination (ion removal, brine processing, contaminant filtration) Pharmaceutical and Biotechnology (drug compound purification, sample preparation, protein separation) Chemical Manufacturing (solvent extraction, chemical purification, catalyst recovery) Environmental Remediation (industrial wastewater treatment, heavy metal removal, pollution control) Medical Diagnostics and Research (blood and plasma separation, point-of-care sample processing, analytical chemistry) TRL 4 LA-UR-26-24077 US Patent No. 11,471,838 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology m.lanl.gov/tech-search

Contact

Point of contact
Satya Srinivasan
Role
not stated on this notice — SAM publishes a role for only about 5% of them, so this may be a contract specialist rather than the contracting officer
Email
licensing@lanl.gov
Secondary
licensing@lanl.gov
Submit questions

Ambiguities and requirements worth clarifying, written as questions you can send before the deadline.

Open email
Capability response

Introduce your firm against this requirement for a Sources Sought or market research notice.

Open email
Request documents

Ask for attachments, drawings or specifications referenced in the notice but not posted.

Open email
Add me to interested vendors

Ask to be listed as an interested vendor so other bidders can find you for teaming.

Open email

Opens in your own mail client, addressed and with a subject line — you write the message. GovSprint never sends anything on your behalf.

Emails open in your mail client and are sent from your address, so the reply comes back to you and the exchange stays yours. Confirm the correct channel and any question deadline on the notice before sending — many solicitations require questions in a specific way.